KEY FEATURES

  • Same programming and menu structure
  • Keypad and Modem sold separately
  • New Processor
  • Dual BUS
  • Diagnostic LEDs
  • 3AMP switch mode power supply
  • Electrical Fuses
  • Grade 3
  • Ideal for larger installations

 


Pyronix Euro 280 Hybrid Control Panel with No Keypad - FPEURO-280

The Pyronix Euro 280 Hybrid Control Panel is a robust and versatile security solution designed for both residential and commercial applications. Supporting up to 280 zones, this hybrid system accommodates both wired and wireless devices, providing flexibility for new installations or system upgrades. Equipped with advanced programming capabilities and compatibility with PyronixCloud services, the panel enables seamless remote control and monitoring. Its modular design allows for customization, ensuring that the system meets the specific needs of each property.

 

WHAT IS INCLUDED:

1x PYRONIX EURO 280 HYBRID CONTROL PANEL WITH NO KEYPAD FPEURO-280

Be the first to Write a Review for this item!

For the best experience and actual camera quality, please adjust the video resolution to 4K.

PYRONIX EURO 280 Hybrid Control Panel (FPEURO-280) Overview

The PYRONIX EURO 280 is a hybrid control panel designed to accommodate both wired and wireless security devices, offering flexibility for medium to large-scale installations. This model is ideal for properties requiring a mix of legacy wired devices and modern wireless technology. It does not include a keypad, providing the flexibility to pair with the keypad of your choice based on the installation requirements.


1. Key Features

System Capacity

  • Hybrid Design:
    • Supports up to 32 wired zones and 64 wireless zones (when paired with a wireless receiver).
  • Expandable:
    • Expandable using zone expanders and additional modules.

Communication

  • Compatible with a range of communication modules for remote monitoring:
    • GSM/GPRS
    • PSTN
    • IP or Wi-Fi modules (additional purchases required).
  • Works with the ProControl+ app when connected to a compatible communicator.

User Management

  • Supports up to 75 user codes, including fob-based or app-based arming/disarming.
  • Assignable user permissions for added security.

Integration

  • Fully compatible with Pyronix wireless peripherals (when a wireless receiver module is installed).
  • Can integrate with third-party systems, such as smart home platforms, via supported communication protocols.

Event Logging

  • Up to 2,000 event memory, allowing detailed system tracking for administrators.

Keypad Options (Sold Separately)

  • Compatible with a wide range of Pyronix keypads, including LED, LCD, or touchscreen models, offering flexibility based on user preferences.

2. Installation Steps

A. Preparation

  1. Determine the number of wired and wireless zones required.
  2. Select the appropriate keypad model and communication modules for the installation.
  3. Plan the wiring layout for wired zones and power.

B. Panel Installation

  1. Mount the EURO 280 panel in a secure, central location to ensure effective communication with devices.
  2. Connect to the main power supply and a backup battery.
  3. Wire any necessary sensors or modules to their respective terminals.

C. Configuring Devices

  1. Wired Zones:

    • Connect wired devices to their designated zones on the panel.
    • Terminate unused zones using resistors as per the manual.
  2. Wireless Zones:

    • Install the wireless receiver module (if needed).
    • Pair wireless devices such as PIRs, magnetic contacts, and smoke detectors.

D. Keypad Setup

  1. Connect the keypad to the panel using the correct wiring terminals.
  2. Power on the system and program the panel via the keypad.

E. Communication Setup

  1. Install the required communication module (e.g., Wi-Fi, GSM).
  2. Configure remote monitoring settings, if applicable.

F. System Programming

  1. Use the keypad or a connected computer to program zones, user codes, and arming/disarming behaviors.
  2. Test all zones and communication settings.

3. Compatibility

  • Compatible with Pyronix Enforcer wireless peripherals (requires a wireless receiver module).
  • Works with ProControl+ app for remote control and monitoring (requires a compatible communicator).
  • Compatible with Pyronix Deltabell external sounders.

4. How It Works

  1. Zone Monitoring:

    • Monitors both wired and wireless zones for unauthorized events.
    • Triggers alarms based on predefined zone behaviors.
  2. Control:

    • Users interact with the system via an external keypad, app, or fob.
  3. Communication:

    • Sends alerts to users or monitoring stations through the configured communicator.

5. Maintenance Tips

  • Battery Maintenance:

    • Check and replace the control panel backup battery every 3–5 years or as indicated.
    • Monitor the battery status of any wireless peripherals.
  • Regular Testing:

    • Perform system tests regularly to ensure all devices are communicating properly.
    • Verify communication module functionality.
  • Firmware Updates:

    • Keep firmware updated via Pyronix-approved methods for improved performance and features.

6. Applications

  • Ideal for medium to large properties requiring hybrid setups.
  • Perfect for commercial properties integrating legacy wired systems with modern wireless devices.
  • Suitable for expanding or upgrading existing wired systems with minimal disruption.